{"title":"Relay","description":null,"products":[{"product_id":"super-b-relais-tbs-rbs-24v500a","title":"Super B relay TBS RBS 24V500A","description":"\u003ch2\u003e Super B relay TBS RBS 24V500A\u003c\/h2\u003e  \u003cp\u003eThe \u003cstrong\u003eSuper B relay TBS RBS 24V500A\u003c\/strong\u003e is a powerful magnetic high-current relay designed for continuous loads of up to \u003cstrong\u003e500 amps DC\u003c\/strong\u003e . It is ideally suited for demanding applications where high currents need to be switched safely and reliably.\u003c\/p\u003e\n\u003cp\u003e The relay can be controlled directly via the \u003cstrong\u003ebattery communication interface (BCI)\u003c\/strong\u003e and is optimally designed for use with \u003cstrong\u003eNomada 12V 105Ah batteries\u003c\/strong\u003e . Its robust construction provides a durable solution for high-current applications in mobile, stationary, and industrial power systems. The TBS RBS is available in both 12 VDC and 24 VDC versions, ensuring maximum operational reliability.\u003c\/p\u003e","brand":"Super B","offers":[{"title":"Incl. 19% VAT","offer_id":57251322593655,"sku":"502-1048","price":275.35,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12(3) of the German VAT Act.","offer_id":57255454212471,"sku":"502-1048","price":231.39,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/502-1048superbtbsrbsjpg-329675.jpg?v=1761422626"},{"product_id":"super-b-relais-tbs-rbs-48v350a","title":"Super B relay TBS RBS 48V350A","description":"\u003ch2\u003eSuper B Relais TBS RBS 48V350A: The Remote-Controlled Battery Main Switch\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent Control\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Super B TBS RBS 48V350A is a highly intelligent relay that can safely and continuously control DC currents of up to 350 amperes thanks to its magnetic design. It serves excellently as a remote-controlled battery main switch and offers an efficient solution for managing high-current applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasy and Flexible Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInstalled in the engine room or battery compartment, the RBS can be conveniently controlled from another location, for example by a small switch on the control panel or by intelligent devices such as a battery monitor. The integrated buttons also enable local operation, while the included 5-wire cable supports flexible external control, accepting both two-wire and single-wire ON\/OFF commands.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Efficiency Through Magnetic Latching\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAs a latching relay, the RBS draws no current from the battery once the contact is closed. This distinguishes it significantly from traditional relays, which require a continuous holding current.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith protection mechanisms against high\/low supply voltage and overheating, as well as a function to remedy welded contacts, the RBS offers reliable operation under all conditions. Furthermore, it complies with the ISO8846 explosion protection standard, qualifying it for use in sensitive environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Design for Optimal Space Utilization\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAs part of the TBS DC Modular family, the RBS boasts a base footprint up to 50% smaller compared to similar products. Ideal for installations where every centimeter counts.\u003c\/p\u003e\n","brand":"Super B","offers":[{"title":"Incl. 19% VAT","offer_id":57251322790263,"sku":"502-1049","price":275.35,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12(3) of the German VAT Act.","offer_id":57255551828343,"sku":"502-1049","price":231.39,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/502-1049superbtbsrbsjpg-329676.jpg?v=1761422626"},{"product_id":"super-b-nomia-bi-stabiles-relais-23130c-12v-260a-kabel-1m","title":"Super B Nomia Bi-stable relay 23130C 12V 260A + cable 1m","description":"\u003ch2\u003eSuper B Nomia 12V 260A Relay with 1m Cable\u003c\/h2\u003e\n\u003cp\u003eThe Super B Nomia bistable relay 23130C with 12V and 260A, including 1 meter of cable, is designed for use with Super B Nomia batteries, including the Nomia 12V100Ah, Nomia 12V160Ah, and Nomia 12V210Ah models. This powerful relay offers a continuous current limit of 190 A at a temperature of 85°C or 185°F. It can be electrically switched on and off, making it a continuously operable unit suitable for DC voltage levels of up to 12V. It also features a high peak current capacity of up to 1500 A.\u003c\/p\u003e\n","brand":"Super B","offers":[{"title":"Incl. 19% VAT","offer_id":57251322986871,"sku":"502-1050","price":170.63,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12 (3) of the German VAT Act.","offer_id":57255542882679,"sku":"502-1050","price":143.39,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/502-1050superbrelaisnomia260ajpg-329677.jpg?v=1761422627"},{"product_id":"votronic-hochleistungs-trennrelais-12v-140-200a","title":"Votronic high-performance isolating relay 12V\/140-200A","description":"\u003ch2\u003eVOTRONIC High-Performance Battery Disconnect Relay 12V\/140-200 A – Reliable Battery Isolation for Vehicles\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVOTRONIC High-Performance Battery Disconnect Relay 12V\/140-200 A\u003c\/strong\u003e ensures efficient and safe isolation between the starter and auxiliary batteries. After switching off the engine, the batteries are automatically disconnected to prevent the starter battery from discharging. When starting the engine, the relay reconnects both batteries in parallel, allowing the alternator to charge both simultaneously.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal for vehicles with high power requirements\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThanks to its powerful design with a load capacity of up to 200 A, the disconnect relay is perfectly suited for vehicles that require a lot of power – such as motorhomes, vans, or expedition vehicles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey product benefits at a glance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003eAutomatic disconnection and parallel connection of the batteries\u003c\/li\u003e\n\n\u003cli\u003eLoad capacity of up to 200 A – ideal for high-power consumers\u003c\/li\u003e\n\n\u003cli\u003eIntegrated freewheeling diode for protection against voltage spikes\u003c\/li\u003e\n\n\u003cli\u003eImproved conductivity thanks to an increased copper content in the high-current conductors\u003c\/li\u003e\n\n\u003cli\u003eLonger service life and higher system efficiency compared to the previous model (2201)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n","brand":"VOTRONIC","offers":[{"title":"Incl. 19% VAT","offer_id":57251368370551,"sku":"305-1081","price":50.69,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12(3) of the German VAT Act.","offer_id":57255491731831,"sku":"305-1081","price":42.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/305-1081trennrelais140-200at1jpg-333500.jpg?v=1761423508"},{"product_id":"victron-cyrix-li-charge-24-48v-230a-intelligent-charge-relay","title":"Victron Cyrix-Li-charge 24\/48V-230A intelligent charge relay","description":"\u003ch2\u003eDiscover the Cyrix Battery Combiner by Victron Energy – An Efficient Solution for Battery Management\u003c\/h2\u003e\n\u003cp\u003eThe Cyrix Battery Combiner is an advanced, microprocessor-controlled relay designed to automatically connect batteries in parallel and disconnect them based on their voltage levels. This intelligent system optimizes the charging and discharging of battery banks by automatically connecting them when a battery is being charged and disconnecting them when the voltage falls below the float voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMain advantages of the Cyrix Battery Combiner:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAutomatic battery management: The Cyrix automatically detects when batteries should be connected or disconnected in parallel based on their current voltage levels, enabling efficient and safe charging and discharging. No voltage drop: Unlike traditional isolation diodes, the Cyrix causes virtually no voltage drop. This means that the output voltage of alternators or battery chargers does not need to be increased to compensate for efficiency losses. Replaces isolation diodes: Cyrix Battery Combiners offer a modern alternative to isolation diodes and improve the performance and efficiency of your system by ensuring that batteries are optimally charged and maintained.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Cyrix Battery Combiner is ideal for a variety of applications requiring the management of multiple battery banks, such as in vehicles, boats, off-grid energy systems, and anywhere efficient energy management is required.\u003c\/p\u003e\n\u003cp\u003eWith the Cyrix Battery Combiner by Victron Energy, you are choosing a high-performance battery management solution that maximizes the lifespan of your batteries while ensuring high energy efficiency for your system.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Incl. 19% VAT","offer_id":57255276282231,"sku":"300-3181","price":174.99,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12 (3) of the German VAT Act.","offer_id":57255498023287,"sku":"300-3181","price":147.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/300-3181t1jpg-332594.jpg?v=1761422337"},{"product_id":"victron-cyrix-li-charge-24-48v-120a-intelligent-charge-relay","title":"Victron Cyrix-Li-charge 24\/48V-120A intelligent charge relay","description":"\u003cp\u003eThe Cyrix-Li-Charge 24\/48V-120A from Victron Energy is an essential accessory for 12V and 24V LiFePO4 battery systems. With its capacity to handle currents of up to 120A, it serves as the perfect addition to the VE.Bus BMS by acting as a battery switch for loads that cannot be switched directly through the VE.Bus BMS.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral function of the Cyrix battery coupler:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe device, a powerful microprocessor-controlled relay, automates the parallel connection of batteries when a specific voltage level is reached, indicating the state of charge, and disconnects them as soon as the voltage falls below a critical value, indicating discharge. The Cyrix battery coupler effectively replaces isolation diodes by operating without any voltage loss, which means that no adjustment of the output voltage of generators or chargers is necessary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation of the Cyrix-Li-Charge 24\/48V 120A:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Cyrix-Li-Charge is activated to connect a battery charger under the following conditions:\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003eThe \"Charge Disconnect\" output of the VE.Bus BMS is active,\u003c\/li\u003e\n\n\u003cli\u003eA voltage of at least 13.7 V (or 27.4 V or 54.8 V) is measured at the battery charger connection,\u003c\/li\u003e\n\n\u003cli\u003eA voltage of 2 V or more is detected at the battery connection (remains inactive if not connected to the battery).\u003c\/li\u003e\n\n\u003cli\u003eThe device immediately disconnects the connection if the control output switches to the \"free floating\" state or if overvoltage or overheating of the cells is detected. After the charging process has been stopped and the cell overvoltage alarm has been reset, the Cyrix reconnects. After two reconnection attempts within 3 seconds, the delay switches to 10 minutes. The Cyrix switches off if the battery voltage falls below 13.5 V, with a delay time of one hour.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant notes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf there is no or only minimal discharge current, the Cyrix remains inactive because the battery voltage exceeds the threshold of 13.5 V. If the voltage of the battery charger immediately reaches 13.7 V or higher again after a disconnection, the Cyrix reactivates the connection after a short delay of 3 seconds.\u003c\/p\u003e\n","brand":"Victron Energy","offers":[{"title":"Incl. 19% VAT","offer_id":57255276773751,"sku":"300-3182","price":81.93,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12(3) of the German VAT Act.","offer_id":57255545799031,"sku":"300-3182","price":68.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/300-3182t1jpg-332595.jpg?v=1761422337"},{"product_id":"victron-cyrix-ct-12-24v-120a-battery-combiner-kit-retail","title":"Victron Cyrix-ct 12\/24V-120A Battery Combiner Kit Retail","description":"\u003ch2\u003eThe Cyrix-ct Battery Combiner Kit by Victron Energy – Optimize Your Battery System\u003c\/h2\u003e\n\u003cp\u003eThe Cyrix-ct battery combiner kit by Victron Energy is the ideal solution for integrating a second or third battery system in your vehicle, boat, motorhome, or anywhere else you need additional power. This kit ensures that all your batteries remain efficiently charged by utilizing the engine's electrical system for charging and isolating the starter battery once charging is complete.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures of the Cyrix-ct Kit:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eComplete Kit:\u003c\/strong\u003e Includes all the necessary components, such as cables, eyelets, and mounting hardware, for a hassle-free installation of the Cyrix-ct.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eIntelligent Battery Monitoring:\u003c\/strong\u003e Prevents unwanted switching and ensures efficient management of the battery system.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eAutomatic Voltage Detection:\u003c\/strong\u003e The Cyrix-ct automatically adapts to 12V or 24V systems.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eNo Voltage Drop:\u003c\/strong\u003e Ensures that the output voltage of the alternators or chargers does not need to be unnecessarily increased.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHow the Cyrix-ct 12V\/24V 120A Battery Combiner Works:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Cyrix battery combiner acts as a high-performance, microprocessor-controlled relay that automatically connects batteries in parallel as soon as one battery reaches a specific voltage level. It disconnects the batteries again when the voltage falls below the maintenance voltage. This system effectively replaces isolation diodes without any voltage drop.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePriority for the Starter Battery:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn a typical setup, the Cyrix-ct ensures that the starter battery always has priority. Once the starter battery is fully charged, the auxiliary batteries are also charged without discharging the starter battery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent Software:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe software of the Cyrix-ct 120 does more than just connect and disconnect based on battery voltage. It monitors the overall voltage trend and intelligently adjusts the switching operations to ensure efficient management of the battery system.\u003c\/p\u003e\n\u003cp\u003eThe Cyrix-ct battery combiner kit by Victron Energy offers an advanced and reliable solution for managing multiple batteries. It ensures that your batteries are optimally charged and supports the efficient use of your energy sources.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScope of Delivery: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003e1x Victron Battery Combiner Cyrix-ct 12V\/24V 120A\u003c\/li\u003e\n\n\u003cli\u003e1x 6m 10mm² battery cable red\u003c\/li\u003e\n\n\u003cli\u003e1x 0.5m 10mm² battery cable black\u003c\/li\u003e\n\n\u003cli\u003e1x 0.2m 1.5mm² battery cable with connector and M8 cable lug\u003c\/li\u003e\n\n\u003cli\u003e2x M8 cable lug with insulation sleeve\u003c\/li\u003e\n\n\u003cli\u003e4x M6 cable lug with insulation sleeve\u003c\/li\u003e\n\n\u003cli\u003e4x cable ties 150mm\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n","brand":"Victron Energy","offers":[{"title":"Incl. 19% VAT","offer_id":57255277003127,"sku":"300-3185","price":105.2,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12 (3) of the German VAT Act.","offer_id":57255497793911,"sku":"300-3185","price":88.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/300-3185t1jpg-332596.jpg?v=1761422341"},{"product_id":"victron-ufr1001e-relais","title":"Victron UFR1001E Relay","description":"\u003ch2\u003eDiscover the UFR1001E – Your Specialist for Grid Monitoring in Electricity Self-Generation\u003c\/h2\u003e\n\u003cp\u003eThe UFR1001E is an advanced monitoring device specifically developed for electricity self-generation systems. It plays a crucial role in monitoring voltage and frequency to ensure compliance with important standards and guidelines. This device meets the requirements of the VDE-AR-N 4105 bdew guideline, the British standards G59\/3, G83\/2, and the Austrian standard ÖVE\/ÖNORM E 8001-4-712:2009 for generators connected to the public grid.\u003c\/p\u003e\n\u003cp\u003eWith the UFR1001E, you ensure that your system not only operates efficiently but also complies with the strict safety and regulatory requirements necessary for grid connection. This is particularly important for ensuring grid stability and security while achieving optimal performance from your energy generation system.\u003c\/p\u003e\n\u003cp\u003eFor detailed information about the UFR1001E, including technical specifications and certifications, we invite you to consult the data sheet and available certificates on the website www.ziehl.de. There you will find the UFR1001E in the grid monitoring group, where additional resources and guides are available.\u003c\/p\u003e\n\u003cp\u003eChoose the UFR1001E for reliable, standards-compliant monitoring of your electricity self-generation system and ensure its safe and efficient integration into the public grid.\u003c\/p\u003e\n","brand":"Victron Energy","offers":[{"title":"Incl. 19% VAT","offer_id":57255277527415,"sku":"305-1577","price":890.12,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12(3) of the German VAT Act.","offer_id":57255495139703,"sku":"305-1577","price":748.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/305-1577t1jpg-333482.jpg?v=1761422345"},{"product_id":"votronic-hochleistungs-trennrelais-12-v-70-a-2200","title":"Votronic high-performance isolating relay 12 V \/ 70 A - 2200","description":"\u003ch2\u003eVOTRONIC High-Performance Disconnect Relay 12 V\/70 A – Reliable Battery Disconnection for Vehicles\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVOTRONIC High-Performance Disconnect Relay 12 V\/70 A\u003c\/strong\u003e ensures efficient and safe disconnection between the starter and onboard batteries. After switching off the engine, the batteries are automatically disconnected to prevent the starter battery from discharging. When starting the engine, the relay reconnects both batteries in parallel, allowing the alternator to charge both simultaneously.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey product benefits at a glance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003eAutomatic disconnection and parallel connection of the batteries\u003c\/li\u003e\n\n\u003cli\u003eRated for up to 70 A\u003c\/li\u003e\n\n\u003cli\u003eIntegrated flyback diode for protection against voltage spikes\u003c\/li\u003e\n\n\u003cli\u003eImproved conductivity thanks to an increased copper content in the high-current conductors\u003cbr\u003e\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"VOTRONIC","offers":[{"title":"Incl. 19% VAT","offer_id":57251278455159,"sku":"305-1079","price":16.59,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/trenn-relais12v-70a2200-333327.png?v=1761421237"},{"product_id":"votronic-umschaltrelais-12-v-60-a-fur-vbcs-triple-2202","title":"Votronic changeover relay 12 V \/ 60 A for VBCS Triple - 2202","description":"\u003ch2\u003eVotronic Changeover Relay 12 V \/ 60 A for VBCS Triple – safe power switching\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVotronic Changeover Relay 12 V \/ 60 A\u003c\/strong\u003e was specially developed for use with the Votronic VBCS Triple and enables reliable switching of circuits in 12-volt onboard networks. It ensures that power sources and consumers are connected safely and in a controlled manner.\u003c\/p\u003e \u003cp\u003eWith a switching capacity of up to 60 amperes, the relay is designed for demanding applications. The robust construction ensures a long service life, while the precise design allows for easy integration into existing Votronic systems.\u003c\/p\u003e \u003cp\u003eIdeally suited for motorhomes, boats, and stationary energy systems, the changeover relay supports stable, safe, and efficient operation of your power supply.\u003c\/p\u003e","brand":"VOTRONIC","offers":[{"title":"Incl. 19% VAT","offer_id":57251261415799,"sku":"303-1148","price":23.25,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12(3) of the German VAT Act.","offer_id":57255520600439,"sku":"303-1148","price":19.54,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/umschalt-relais-12v-60a2202-333283.jpg?v=1761420684"},{"product_id":"victron-cyrix-ct-12-24v-120a-batteriekoppler-trennrelais-batterieschutz","title":"Victron Cyrix-ct 12\/24V 120A battery coupler isolating relay battery protection","description":"\u003ch2\u003eCyrix 120A Battery Isolator\u003c\/h2\u003e\n\u003cp\u003eThe cyrix battery isolator is a high-performance microprocessor-controlled relay that automatically connects batteries in parallel when one of them reaches a preset voltage level (indicating that the battery is being charged) and disconnects the batteries again when the voltage drops below the maintenance voltage level (indicating that one or both batteries are currently being discharged).\u003cbr\u003ecyrix battery isolators are ideal for replacing isolation diodes. Their main feature is that there is virtually no voltage drop, so the output voltage of the alternators or battery chargers does not need to be increased.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eProduct features\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003emaximum continuous current: 120 A \r\n\n\u003c\/li\u003e\n\n\u003cli\u003eallowable starting current (5s): 180 A \r\n\n\u003c\/li\u003e\n\n\u003cli\u003esuitable for 12 V or 24 V systems (automatic detection) \r\n\n\u003c\/li\u003e\n\n\u003cli\u003evirtually no voltage drop \r\n\n\u003c\/li\u003e\n\n\u003cli\u003eno D+ signal required: The Cyrix battery isolator switches depending on the battery voltage \r\n\n\u003c\/li\u003e\n\n\u003cli\u003ebattery temperature protection: In case of high overload, the battery is automatically disconnected \u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eIntelligent battery monitoring to prevent unwanted switching\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eSome battery isolators (also called voltage-controlled relays or split charge relays) disconnect a battery when a short but high-amperage load occurs. Sometimes a battery isolator will also not connect a large but discharged battery bank because the DC voltage immediately drops below the disconnect threshold after the batteries are connected. The software of the Cyrix-ct 12\/24 takes on more functions than simply connecting and disconnecting based on the battery voltage and with a fixed time delay.\u003cbr\u003eThe Cyrix-ct 12\/24 monitors the general trend (voltage is rising or falling) and only reverses a previous action if the trend has reversed during a certain period. The time delay depends on how much the voltage deviates from the trend. \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNo voltage drop\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003ecyrix battery isolators are ideal for replacing isolation diodes. Their main feature is that there is virtually no voltage drop, so the output voltage of the alternators or battery chargers does not need to be increased. \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eBidirectional voltage detection and power supply from both batteries\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe Cyrix measures the voltage of the two connected batteries. It therefore also switches on if, for example, the additional battery is being charged by a battery charger. The Cyrix-ct 12\/24 has a dual power supply.\u003cbr\u003eIt therefore also closes even if the voltage on one of the batteries is too low to power the Cyrix.\u003cbr\u003eTo prevent accidental operation during installation or if one of the batteries has been disconnected, the Cyrix-ct 12\/24 does not close if the voltage on one of the two battery connections is below 2 V (12 V battery) or 4 V (24 V battery). \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eProtection against overheating (e.g. due to prolonged overload)\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe Cyrix disconnects if the contact temperature is too high and reconnects after the temperature has dropped. \u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\u003cb\u003eParallel connection for emergencies (Start Assist)\u003c\/b\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003eThe Cyrix can also be switched on via a push button (Cyrix remains in operation for 30 seconds) or via a switch to manually connect the batteries in parallel. This is particularly useful in an emergency if the starter battery is discharged or damaged.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTechnical information\u003c\/b\u003e\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Incl. 19% VAT","offer_id":57255201210743,"sku":"300-3190","price":52.6,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12(3) of the German VAT Act.","offer_id":57255497728375,"sku":"300-3190","price":44.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/cyrix-ct-120a-frontjpg-332413.jpg?v=1761420698"},{"product_id":"victron-cyrix-ct-12-24v-230a-batteriekoppler-trennrelais-batterieschutz","title":"Victron Cyrix-ct 12\/24V 230A battery coupler isolating relay battery protection","description":"\u003ch2\u003eCyrix Battery Combiner\u003c\/h2\u003e\n\u003cp\u003eThe cyrix battery combiner is a high-performance microprocessor-controlled relay that automatically connects batteries in parallel when one of them reaches a preset voltage level (indicating that the battery is being charged) and disconnects the batteries again when the voltage drops below the maintenance voltage level (indicating that one or both batteries are currently being discharged). cyrix battery combiners are ideal for replacing isolation diodes.\u003cbr\u003e\nIts main feature is that there is virtually no voltage drop, so the output voltage of the alternators or battery chargers does not need to be increased.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eProduct features\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003emaximum continuous current: 230 A\u003c\/li\u003e\n\n\u003cli\u003epermissible starting current (5s): 500 A\u003c\/li\u003e\n\n\u003cli\u003esuitable for 12V or 24 V systems (automatic detection)\u003c\/li\u003e\n\n\u003cli\u003evirtually no voltage drop\u003c\/li\u003e\n\n\u003cli\u003eno D+ signal required: The Cyrix battery combiner switches depending on the battery voltage\u003c\/li\u003e\n\n\u003cli\u003ebattery temperature protection: In the event of severe overload, the battery is automatically disconnected\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eIntelligent battery monitoring to prevent unwanted switching\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eSome battery combiners (also called voltage-controlled relays or split charge relays) disconnect a battery when a short but high-amperage load occurs. Sometimes a battery combiner will also not connect a large but discharged battery bank because the DC voltage immediately drops below the disconnection threshold after the batteries are connected. The software of the Cyrix-ct 12\/24 takes on more functions than simply connecting and disconnecting based on the battery voltage and with a fixed time delay.\u003cbr\u003e\nThe Cyrix-ct 12\/24 monitors the general trend (voltage is rising or falling) and only reverses a previous action if the trend has reversed during a certain period. The time delay depends on how much the voltage deviates from the trend.\u003cbr\u003e\n \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNo voltage drop\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eCyrix battery combiners are ideal for replacing isolation diodes.\u003cbr\u003e\nIts main feature is that there is virtually no voltage drop, so the output voltage of the alternators or battery chargers does not need to be increased.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\n\u003cb\u003eBidirectional voltage detection and power supply from both batteries\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe Cyrix measures the voltage of the two connected batteries. It therefore also switches on if, for example, the additional battery is being charged by a battery charger. The Cyrix-ct 12\/24 has a dual power supply. It therefore also closes even if the voltage on one of the batteries is too low to power the Cyrix.\u003cbr\u003e\nTo prevent accidental operation during installation or if one of the batteries has been disconnected, the Cyrix-ct 12\/24 does not close if the voltage at one of the two battery connections is below 2 V (12 V battery) or 4 V (24 V battery).\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\n\u003cb\u003eProtection against overheating (e.g. due to prolonged overload)\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe Cyrix disconnects if the contact temperature is too high and reconnects after the temperature has dropped.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\n\u003cb\u003eParallel connection for emergencies (Start Assist)\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe Cyrix can also be switched on via a push button (Cyrix remains in operation for 30 seconds) or via a switch to manually connect the batteries in parallel. This is particularly useful in an emergency if the starter battery is discharged or damaged.\u003c\/p\u003e\n","brand":"Victron Energy","offers":[{"title":"Incl. 19% VAT","offer_id":57255201309047,"sku":"300-3191","price":130.48,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12(3) of the German VAT Act.","offer_id":57255511622007,"sku":"300-3191","price":109.65,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/cyrix-ct-230a-frontjpg-332414.jpg?v=1761420699"},{"product_id":"victron-cyrix-i-12-24v-400-a-batteriekoppler-trennrelais-batterieschutz","title":"Victron Cyrix-i 12\/24V 400 A battery coupler isolating relay battery protection","description":"\u003ch2\u003eCyrix-i intelligent battery combiner\u003c\/h2\u003e\n\u003cp\u003eThe cyrix battery combiner is a high-performance microprocessor-controlled relay that automatically connects batteries in parallel when one of them reaches a preset voltage level (indicating that the battery is being charged) and disconnects the batteries from each other when the voltage drops below the maintenance voltage level (indicating that one or both batteries are currently being discharged.\u003cbr\u003e\ncyrix battery combiners are ideally suited to replace isolation diodes. Their main feature is that there is practically no voltage loss, so the output voltage of the alternators or battery chargers does not need to be increased.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eProduct features\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003emaximum continuous current: 400 A\u003c\/li\u003e\n\n\u003cli\u003epermissible starting current (1s): 2000 A\u003c\/li\u003e\n\n\u003cli\u003esuitable for 12V or 24 V systems (automatic detection)\u003c\/li\u003e\n\n\u003cli\u003epractically no voltage loss\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eNew: advanced battery monitoring prevents unwanted switching\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eIn some battery control relays, short-term high currents trigger disconnection. It can also happen that a large but empty battery bank cannot be connected because the voltage drop when connecting falls below the switching-off threshold.\u003cbr\u003e\nThe software stored in the Cyrix-i does not only refer to voltage values and fixed time intervals. Rather, Cyrix-i takes the trend (voltage\/time – curves) into account and only intervenes when the trend changes over a certain time interval. The time delay is proportional to the voltage deviation from the trend curve. In addition, four different switching\/time curves can be set\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAutomatic range selection at 12\/24V\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eCyrix-i automatically detects the applied system voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNo voltage loss\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe Cyrix-i battery control is the alternative to isolation diodes. Since there is practically no voltage loss, the increase in charging voltage at the alternator or charger, which is otherwise usual to compensate for loss, is not required.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePriority connection for the starter battery\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eTypically, the alternator is connected directly to the starter battery. The onboard battery, possibly the bow thruster battery and others are connected via Cyrix-i devices. Only when the starter battery has reached the corresponding voltage does Cyrix-i add the other batteries to parallel charging.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eBidirectional voltage measurement and power supply\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eCyrix-i measures the voltage values of the connected battery banks. It therefore also typically reacts when the onboard battery is being charged by a charger. The Cyrix-i has a dual power supply. It therefore also works when one of the connected batteries has insufficient voltage for Cyrix-i operation.\u003cbr\u003e\nTo prevent unwanted switching during installation or after loosening the battery connection, Cyrix-I will not switch if the voltage value of one of the two battery connections drops to less than 2V (12V battery), 4V (24V battery) or 8V (48V battery).\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eParallel connection in an emergency\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe Cyrix-i can also be switched on via a push button (Cyrix-i then remains switched on for 30 sec.). There is also a switch for manual parallel connection of the batteries. This is particularly helpful if the starter battery is empty or damaged in an emergency.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n","brand":"Victron Energy","offers":[{"title":"Incl. 19% VAT","offer_id":57255201407351,"sku":"300-3192","price":278.16,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12 (3) of the German VAT Act.","offer_id":57255506575735,"sku":"300-3192","price":233.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/300-3192t1jpg-332415.jpg?v=1761420701"},{"product_id":"victron-cyrix-i-24-48-v-400-a-batteriekoppler-trennrelais-batterieschutz","title":"Victron Cyrix-i 24\/48V 400A Battery Coupler Isolator Relay Battery Protection","description":"\u003ch2\u003eCyrix-i intelligent battery isolator\u003c\/h2\u003e\n\u003cp\u003eThe cyrix battery isolator is a high-performance microprocessor-controlled relay that automatically connects batteries in parallel when one of them reaches a preset voltage level (indicating that the battery is being charged) and disconnects the batteries again when the voltage drops below the float voltage (indicating that one or both batteries are currently being discharged.\u003cbr\u003e\ncyrix battery isolators are ideally suited to replace isolation diodes. Their main feature is that there is practically no voltage loss, so the output voltage of the alternators or battery chargers does not need to be increased.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eProduct features\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003emaximum continuous current: 400 A\u003c\/li\u003e\n\n\u003cli\u003epermissible starting current (1s): 2000 A\u003c\/li\u003e\n\n\u003cli\u003esuitable for 24 V or 48 V systems (automatic detection)\u003c\/li\u003e\n\n\u003cli\u003epractically no voltage loss\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eNew: advanced battery monitoring prevents unwanted switching\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eIn some battery control relays, short-term high currents trigger disconnection. It can also happen that a large but empty battery bank cannot be connected because the voltage drop when connecting falls below the switching-off threshold.\u003cbr\u003e\nThe software stored in the Cyrix-i does not only refer to voltage values and fixed time intervals. Rather, Cyrix-i takes the trend (voltage\/time – curves) into account and only intervenes when the trend changes over a certain time interval. The time delay is proportional to the voltage deviation from the trend curve. In addition, four different switching\/time curves can be set\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAutomatic range selection for 12\/24V\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eCyrix-i automatically detects the applied system voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNo voltage loss\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe Cyrix-i battery control is the alternative to isolation diodes. Since there is practically no voltage loss, the increase in charging voltage at the alternator or charger, which is otherwise customary to compensate for loss, is not required.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePriority connection for the starter battery\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eTypically, the alternator is connected directly to the starter battery. The onboard battery, possibly the bow thruster battery and others are connected via Cyrix-i devices. Only when the starter battery has reached the corresponding voltage does Cyrix-i connect the other batteries for parallel charging.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eBidirectional voltage measurement and power supply\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eCyrix-i measures the voltage values of the connected battery banks. It therefore also typically reacts when the onboard battery is being charged by a charger. The Cyrix-i has a dual power supply. It therefore also works when one of the connected batteries has insufficient voltage for Cyrix-i operation.\u003cbr\u003e\nTo prevent unwanted switching during installation or after loosening the battery connection, Cyrix-I will not switch if the voltage value of one of the two battery connections drops to less than 4V (24V battery) or 8V (48V battery).\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eParallel connection in an emergency\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe Cyrix-i can also be switched on via a push button (Cyrix-i then remains switched on for 30 sec.). There is also a switch for manual parallel connection of the batteries. This is particularly helpful if the starter battery is empty or damaged in an emergency.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n","brand":"Victron Energy","offers":[{"title":"Incl. 19% VAT","offer_id":57255201440119,"sku":"300-3193","price":278.16,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12(3) of the German VAT Act.","offer_id":57255487865207,"sku":"300-3193","price":233.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/cyrix-ct-400ajpg-332419.jpg?v=1761420703"},{"product_id":"victron-cyrix-li-load-12-24v-120a-batteriekoppler-trennrelais-batterieschutz","title":"Victron Cyrix Li-load 12\/24V 120A battery coupler isolating relay battery protection","description":"\u003ch2\u003eCyrix Battery Isolator Li-ion Series: Li-Load\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eOperation of the Cyrix Li-Load\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe Cyrix battery isolator protects the battery from deep discharge by loads.\u003cbr\u003e\nThe Cyrix Li-Load switches off when its control input detects a \"free floating\" state (open circuit).\u003cbr\u003e\nIf the battery voltage recovers after switching off (this happens when no other loads are connected to the battery), the BMS output goes high and the Cyrix switches back on after 30 seconds. After 3 power-on attempts, the Cyrix remains switched off until the voltage has risen above 13 V (or 26 V) for at least 30 seconds (this indicates that the battery is being recharged).\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eProduct features\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003eProtects the battery from deep discharge by loads\u003c\/li\u003e\n\n\u003cli\u003eContinuous current: 120 A\u003c\/li\u003e\n\n\u003cli\u003eSuitable for 12 V and 24 V systems, automatic detection\u003c\/li\u003e\n\n\u003cli\u003eIntelligent microprocessor control\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n","brand":"Victron Energy","offers":[{"title":"Incl. 19% VAT","offer_id":57255201538423,"sku":"300-3194","price":70.81,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12(3) of the German VAT Act.","offer_id":57255483408759,"sku":"300-3194","price":59.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/li-load-332416.jpg?v=1761420704"},{"product_id":"victron-cyrix-li-charge-12-24v-120a-batteriekoppler-relais-batterieschutz-lithium","title":"Victron Cyrix Li-charge 12\/24V 120A battery coupler relay battery protection lithium","description":"\u003ch2\u003eCyrix Li-ion Battery Coupler Series: Li-Charge\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eOperation of the Cyrix Li-Charge \u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe Cyrix Li-Charge connects a battery charger with a 3-second delay:\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003eif the \"Charge Disconnect\" output of the VE. Bus BMS is high and\u003c\/li\u003e\n\n\u003cli\u003eif it measures 13.7 V (or 27.4 V) or more at its battery charger connection and\u003c\/li\u003e\n\n\u003cli\u003eif it measures 2 V or more at its battery connection (the Cyrix remains open if it is not connected to the battery).\n\t\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eThe Cyrix Li-Charge switches off immediately if its control input reaches the \"free floating\" state (open circuit), or if it detects overvoltage or overtemperature of a cell. Generally, an overvoltage alarm is reset shortly after charging stops.\u003cbr\u003e\n\tThe Cyrix then reconnects the charger after a 3-second delay. After two attempts to reconnect the device at 3-second intervals, this delay is extended to 10 minutes. Whenever the battery voltage is below 13.5 V (or 27 V or 54 V), the Cyrix switches off after a 1-hour delay.\u003cbr\u003e\n\tNote 1: If the discharge current is zero or very low, the Cyrix will not switch off shortly after the charger is switched off and\/or disconnected because the battery voltage remains above 13.5 V.\u003cbr\u003e\n\tNote 2: If the output of the battery charger immediately rises back to 13.7 V or more after the Cyrix has switched off, the Cyrix will switch back on after a 3-second delay.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eProduct features\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eProtects the battery against over-discharge by loads\u003c\/li\u003e\n\n\u003cli\u003eContinuous current: 120 A\u003c\/li\u003e\n\n\u003cli\u003eSuitable for 12 V and 24 V systems, automatic detection\u003c\/li\u003e\n\n\u003cli\u003eIntelligent microprocessor control\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n","brand":"Victron Energy","offers":[{"title":"Incl. 19% VAT","offer_id":57251737010551,"sku":"300-3195","price":81.93,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12(3) of the German VAT Act.","offer_id":57255511163255,"sku":"300-3195","price":68.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/li-charge-120jpg-332417.jpg?v=1761420705"},{"product_id":"victron-cyrix-li-load-12-24v-230a-batteriekoppler-trennrelais-batterieschutz","title":"Victron Cyrix Li-load 12\/24V 230A battery coupler isolating relay battery protection","description":"\u003ch2\u003eCyrix Li-ion Battery Coupler Series: Li-Load\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eOperation of the Cyrix Li-Load\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe Cyrix battery coupler protects the battery from deep discharge by loads.\u003cbr\u003e\nThe Cyrix Li-Load switches off when its control input detects a \"free floating\" state (open circuit).\u003cbr\u003e\nIf the battery voltage recovers after switching off (this happens when no other loads are connected to the battery), the BMS output goes high and the Cyrix switches back on after 30 seconds. After 3 power-on attempts, the Cyrix remains switched off until the voltage has risen above 13 V (or 26 V) for at least 30 seconds (this indicates that the battery is being recharged).\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eProduct features\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003eProtects the battery from deep discharge by loads\u003c\/li\u003e\n\n\u003cli\u003eContinuous current: 230 A\u003c\/li\u003e\n\n\u003cli\u003eSuitable for 12 V and 24 V systems, automatic detection\u003c\/li\u003e\n\n\u003cli\u003eIntelligent microprocessor control\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n","brand":"Victron Energy","offers":[{"title":"Incl. 19% VAT","offer_id":57255201636727,"sku":"300-3196","price":174.99,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12(3) of the German VAT Act.","offer_id":57255506215287,"sku":"300-3196","price":147.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/cyrix-li-loadjpg-332418.jpg?v=1761420706"},{"product_id":"victron-cyrix-li-charge-12-24v-230a-batteriekoppler-relais-batterieschutz-lithium","title":"Victron Cyrix Li-charge 12\/24V 230A battery coupler relay battery protection lithium","description":"\u003ch2\u003eCyrix Li-ion Battery Coupler Series: Li-Charge\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eOperation of the Cyrix Li-Charge \u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe Cyrix Li-Charge connects a battery charger with a 3-second delay:\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003ewhen the \"Charge Disconnect\" output of the VE. Bus BMS is high and\u003c\/li\u003e\n\n\u003cli\u003ewhen it measures 13.7 V (or 27.4) or more at its battery charger connection and\u003c\/li\u003e\n\n\u003cli\u003ewhen it measures 2 V or more at its battery connection (the Cyrix remains open if it is not connected to the battery).\n\t\u003cp\u003eThe Cyrix Li-Charge switches off immediately if its control input reaches the \"free floating\" state (open circuit), detects overvoltage in a cell, or detects overtemperature in a cell.\u003cbr\u003e\n\tGenerally, an overvoltage alarm in a cell is reset shortly after charging stops. The Cyrix then reconnects the charger after a 3-second delay. After two attempts to reconnect the device at 3-second intervals, this delay time is extended to 10 minutes.\u003cbr\u003e\n\tWhenever the battery voltage is below 13.5 V (or 27 V or 54 V), the Cyrix switches off after a 1-hour delay.\u003cbr\u003e\n\tNote 1: If the discharge current is zero or only a very low discharge current is present, the Cyrix will not switch off shortly after the charger is switched off and\/or disconnected because the battery voltage remains above 13.5 V.\u003cbr\u003e\n\tNote 2: If the output of the battery charger immediately rises back to 13.7 V or more after the Cyrix has switched off, the Cyrix switches back on after a 3-second delay.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eProduct features\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eProtects the battery from over-discharge by loads\u003c\/li\u003e\n\n\u003cli\u003eContinuous current: 230 A\u003c\/li\u003e\n\n\u003cli\u003eSuitable for 12 V and 24 V systems, automatic detection\u003c\/li\u003e\n\n\u003cli\u003eintelligent microprocessor control\u003cspan style=\"display: none;\"\u003e \u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n","brand":"Victron Energy","offers":[{"title":"Incl. 19% VAT","offer_id":57255201735031,"sku":"300-3197","price":174.99,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12 (3) of the German VAT Act.","offer_id":57255487013239,"sku":"300-3197","price":147.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/cyrix-li-chargejpg-332420.jpg?v=1761420708"},{"product_id":"victron-cyrix-li-ct-12-24v-120a-batteriekoppler-trennrelais","title":"Victron Cyrix-Li-ct 12\/24V 120A battery coupler isolating relay","description":"\u003ch2\u003eCyrix-Li-ct Intelligent Battery Coupler\u003c\/h2\u003e\n\u003cp\u003eThe Cyrix-Li-ct connects a lead-acid starter battery and a LiFePO4 battery:\u003c\/p\u003e\n\u003cp\u003e- when the \"Charge Disconnect\" output of the VE. Bus BMS is high and - when it measures 13.4 V (or 26.8 V) or more at its power terminals.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe Cyrix switches off immediately:\u003c\/p\u003e\n\u003cp\u003e- when its control output reaches the \"free floating\" state (open circuit), detects overvoltage or overtemperature of a cell and\/or - when the battery voltage drops below 13.2 V.\u003c\/p\u003e\n\u003cp\u003eStart Assist function: a short positive pulse closes the relay for 30 seconds (see figure on page 2). A built-in TVS diode limits the voltage spike that can occur when the Cyrix suddenly switches off due to cell overvoltage or overtemperature.\u003c\/p\u003e\n","brand":"Victron Energy","offers":[{"title":"Incl. 19% VAT","offer_id":57255208026487,"sku":"300-3002","price":81.93,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12(3) of the German VAT Act.","offer_id":57255452049783,"sku":"300-3002","price":68.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/1472133279uploaddocuments775500-cyr010230410-cyrix-li-ct-1224v-230a-intelligent-li-ion-batt-combfrontpng-332305.png?v=1761420829"},{"product_id":"victron-cyrix-li-ct-12-24v-230a-batteriekoppler-trennrelais","title":"Victron Cyrix-Li-ct 12\/24V 230A battery coupler isolating relay","description":"\u003cstrong\u003eIntelligent battery coupler Cyrix-Li-ct\u003c\/strong\u003e\u003cbr\u003e The functionality of the Cyrix-Li-ct is the same as that of the Cyrix-ct.\u003cbr\u003e The Cyrix-Li-ct connects a lead-acid starter battery and a LiFePO4 battery:\u003cbr\u003e - if the \"Charge Disconnect\" output of the VE. Bus BMS is high and\u003cbr\u003e - if it measures 13.4 V (or 26.8 V) or more at its power terminals.\u003cbr\u003e\u003cbr\u003e The Cyrix shuts down immediately: - when its control output reaches the \"free floating\" state (open circuit), indicates a cell overvoltage or cell overtemperature and\/or - when the battery voltage drops below 13.2 V\u003cbr\u003e Start Assist Function:\u003cbr\u003e A short positive pulse closes the relay for 30 seconds (see figure on page 2)\u003cbr\u003e \u003cbr\u003eA built-in TVS diode limits the voltage spike that can occur when the Cyrix suddenly shuts down due to cell overvoltage or overtemperature.","brand":"Victron Energy","offers":[{"title":"Incl. 19% VAT","offer_id":57255209828727,"sku":"300-3004","price":174.99,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12 (3) of the German VAT Act.","offer_id":57255487635831,"sku":"300-3004","price":147.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/cyr010230410-cyrix-li-ct-1224v-230a-intelligent-li-ion-batt-combfrontpng-332307.png?v=1761420931"},{"product_id":"victron-cyrix-li-load-24-48v-120a-batteriekoppler-trennrelais-batterieschutz-lithium","title":"Victron Cyrix-Li-Load 24\/48V 120A battery coupler isolating relay battery protection lithium","description":"\u003ch2\u003eCyrix Li-ion Battery Isolator Series: Li-Load\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eOperation of the Cyrix Li-Load\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe Cyrix battery isolator protects the battery from over-discharge by loads.\u003cbr\u003e\nThe Cyrix Li-Load switches off when its control input reaches the \"free floating\" state (open circuit). If the battery voltage recovers after switching off (this happens when no other loads are connected to the battery), the BMS output goes high and the Cyrix switches back on after 30 seconds. After 3 power-on attempts, the Cyrix remains switched off until the voltage has risen above 13 V (or 26 V or 52 V) for at least 30 seconds (this is an indication that the battery is being recharged). Alternatively, battery protectors can be used (advantage: very low power consumption).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eProduct features\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003eProtects the battery from over-discharge by loads\u003c\/li\u003e\n\n\u003cli\u003eContinuous current: 120 A\u003c\/li\u003e\n\n\u003cli\u003eSuitable for 24V and 48V systems, automatic detection\u003c\/li\u003e\n\n\u003cli\u003eIntelligent microprocessor control\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n","brand":"Victron Energy","offers":[{"title":"Incl. 19% VAT","offer_id":57255216120183,"sku":"300-3010","price":70.81,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12(3) of the German VAT Act.","offer_id":57255497367927,"sku":"300-3010","price":59.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/cyrix-li-load-2448120png-332335.png?v=1761421107"},{"product_id":"votronic-switch-unit-40","title":"Votronic Switch Unit 40 - 2071","description":"\u003ch3\u003eSwitch Unit 40 12\/24V 40-60A\u003c\/h3\u003e\n\u003cp\u003eThe VOTRONIC Switch Units operate on the basis of a bistable power relay. Their own power consumption is extremely low. They are particularly suitable as a remote-controlled main switch or as a load relay that is intended to remain switched on for long periods. The current rating is 40 or 100 A.\u003cbr\u003e\n\u003cbr\u003e\nThe Switch Units can be remotely controlled by a simple switch (1-pole ON \/ OFF).\u003cbr\u003e\n\u003cbr\u003e\nIn addition, the consumers can also be switched on or off manually at the relay via an EMERGENCY-ON function (EMERGENCY switch).\u003cbr\u003e\n\u003cbr\u003e\n\u003cb\u003eThe range of applications extends from motorhomes and boats to emergency vehicles:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \n\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \n\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003eSimple control via a simple ON \/ OFF switch\u003c\/li\u003e\n\n\u003cli\u003eHigh switching currents, briefly highly overloadable\u003c\/li\u003e\n\n\u003cli\u003eUsable as a battery main switch via a simple ON \/ OFF switch (remotely controllable)\u003c\/li\u003e\n\n\u003cli\u003eExternally visible switching status indicator\u003c\/li\u003e\n\n\u003cli\u003eElectronic delay prevents overly rapid reaction, e.g. to voltage drops or the switching on of high-power consumers\u003c\/li\u003e\n\n\u003cli\u003eSuitable for continuous operation (very low own power consumption \/ compliant with EN13976).\u003c\/li\u003e\n\n\u003cli\u003eNo own power consumption when switched off via an external switch (remote control)\u003c\/li\u003e\n\n\u003cli\u003eAutomatic shut-off at 8.5 V low voltage (minimum operating voltage of the Switch Unit\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n","brand":"VOTRONIC","offers":[{"title":"Incl. 19% VAT","offer_id":55569137893751,"sku":"303-1085","price":60.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/303-1085-1jpg-333096.jpg?v=1761420243"},{"product_id":"victron-batteryprotect-12-24v-65a","title":"Victron BatteryProtect 12\/24V 65A","description":"\u003ch2\u003eBatteryProtect 12\/24V 65A by Victron Battery Protection\u003c\/h2\u003e\n\u003cp\u003eThe BatteryProtect disconnects the battery from non-essential loads before it is fully discharged (which would \ndamage it) or before it no longer has enough energy to start the engine.\u003c\/p\u003e\n\u003cb\u003e12\/24 V automatic voltage range detection\u003c\/b\u003e\n\u003cp\u003eThe BatteryProtect automatically detects the system voltage.\u003c\/p\u003e\n\u003cb\u003eEasy programming\u003c\/b\u003e\n\u003cp\u003e\nThe BatteryProtect can be set to switch on or off at several different voltages.\nThe seven-segment display then indicates which setting has been selected.\u003c\/p\u003e\n\u003cb\u003eA special setting for lithium-ion batteries\u003c\/b\u003e\n\u003cp\u003eIn this mode, the BatteryProtect can be controlled by the VE.Bus BMS.\nNote: The BatteryProtect can also be used as a load isolator between a battery charger and a Li-ion battery. See the wiring diagram in the manual.\u003c\/p\u003e\n\u003cb\u003eExtremely low power consumption\u003c\/b\u003e\n\u003cp\u003eThis is important in the case of lithium-ion batteries, especially after switching off due to a low\nvoltage level.\nPlease also refer to our data sheet on lithium-ion batteries and the VE.Bus BMS manual for further\ninformation.\u003c\/p\u003e\n\u003cb\u003eOvervoltage protection\u003c\/b\u003e\n\u003cp\u003e\nTo prevent sensitive loads from being damaged by overvoltage, the load is always switched off\nwhen the DC voltage exceeds 16 V or 32 V.\u003c\/p\u003e\n\u003cb\u003eExplosion protection\u003c\/b\u003e\n\u003cp\u003e\nNo relays, but MOSFET switches, and therefore no sparking.\nDelayed alarm output\nThe alarm output is activated when the battery voltage falls below the preset\ncut-off value for more than 12 seconds. Starting the engine therefore does not activate the alarm. The alarm output is a\nshort-circuit protected open collector output, which is connected to the negative (minus) rail. Max. current 50 mA.\nThe alarm output is normally used to activate an audible signal, an LED, or a relay.\u003c\/p\u003e\n\u003cb\u003eLoad cut-off and reconnection delay\u003c\/b\u003e\n\u003cp\u003e\nThe load is switched off 90 seconds after the alarm is activated. If the battery voltage rises\n(for example, after the engine has been started) back up to the reconnection threshold within this period, the load will not\nbe switched off.\nThe load is reconnected 30 seconds after the battery voltage has exceeded the specified voltage value for reconnection\nagain.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Incl. 19% VAT","offer_id":57251259449719,"sku":"300-3121","price":39.45,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12 (3) of the German VAT Act.","offer_id":57255547666807,"sku":"300-3121","price":33.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/batteryprotect-12-24v-65a-frontpng-332382.png?v=1761420617"},{"product_id":"victron-batteryprotect-12-24v-100a","title":"Victron BatteryProtect 12\/24V-100A","description":"\u003ch2\u003eBatteryProtect 12\/24V 100A by Victron Battery Protection\u003c\/h2\u003e\n\u003cp\u003eThe BatteryProtect disconnects the battery from the less important consumers before it is completely discharged (which would \ndamage it) or before it no longer has enough energy to start the engine.\u003c\/p\u003e\n\u003cb\u003e12\/24 V automatic voltage range detection\u003c\/b\u003e\n\u003cp\u003eThe BatteryProtect automatically detects the system voltage.\u003c\/p\u003e\n\u003cb\u003eEasy programming\u003c\/b\u003e\n\u003cp\u003e\nThe BatteryProtect can be set to switch on or off at several different voltages.\nThe seven-segment display then indicates which setting has been selected.\u003c\/p\u003e\n\u003cb\u003eA special setting for lithium-ion batteries\u003c\/b\u003e\n\u003cp\u003eIn this mode, the BatteryProtect can be controlled by the VE.Bus BMS.\nNote: The BatteryProtect can also be used as a load disconnect between a battery charger and a Li-ion battery. See the wiring diagram in the manual.\u003c\/p\u003e\n\u003cb\u003eExtremely low power consumption\u003c\/b\u003e\n\u003cp\u003eThis is important in the case of lithium-ion batteries, especially after switching off due to a low\nvoltage level.\nPlease also refer to our data sheet on lithium-ion batteries and the VE.Bus BMS manual for further\ninformation.\u003c\/p\u003e\n\u003cb\u003eOvervoltage protection\u003c\/b\u003e\n\u003cp\u003e\nTo prevent sensitive consumers from being damaged by overvoltage, the load is always switched off\nwhen the DC voltage exceeds the value of 16 V or 32 V.\u003c\/p\u003e\n\u003cb\u003eExplosion protection\u003c\/b\u003e\n\u003cp\u003e\nNo relays, but MOSFET switches, and therefore no sparking.\nOutput for delayed alarm\nThe alarm output is activated when the battery voltage falls below the preset value\nfor switching off for more than 12 seconds. Therefore, starting the engine does not activate the alarm. The alarm output is a\nshort-circuit protected open collector output, which is connected to the negative (minus) rail. Max. current 50 mA.\nThe alarm output is normally used to activate an acoustic signal, an LED, or a relay.\u003c\/p\u003e\n\u003cb\u003eLoad disconnection and reconnection delay\u003c\/b\u003e\n\u003cp\u003e\nThe load is switched off 90 seconds after the alarm is activated. If the battery voltage rises\n(for example, after the engine has been started) again to the threshold for reconnection within this period, the load will not\nbe switched off.\nThe load is reconnected 30 seconds after the battery voltage has exceeded the specified voltage value for reconnection\n.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Incl. 19% VAT","offer_id":57255198065015,"sku":"300-3122","price":57.66,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12(3) of the German VAT Act.","offer_id":57255539835255,"sku":"300-3122","price":48.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/51qtd4cfsvlpng-332383.png?v=1761420618"},{"product_id":"victron-batteryprotect-12-24v-220a","title":"Victron BatteryProtect 12\/24V-220A","description":"\u003ch2\u003eBatteryProtect 12\/24V 220A by Victron Battery Protection\u003c\/h2\u003e\n\u003cp\u003eThe BatteryProtect disconnects the battery from non-essential loads before it is fully discharged (which would \ndamage it) or before it no longer has enough energy to start the engine.\u003c\/p\u003e\n\u003cb\u003e12\/24 V automatic voltage range detection\u003c\/b\u003e\n\u003cp\u003eThe BatteryProtect automatically detects the system voltage.\u003c\/p\u003e\n\u003cb\u003eEasy programming\u003c\/b\u003e\n\u003cp\u003e\nThe BatteryProtect can be set to switch on or off at several different voltages.\nThe seven-segment display then indicates which setting has been selected.\u003c\/p\u003e\n\u003cb\u003eA special setting for lithium-ion batteries\u003c\/b\u003e\n\u003cp\u003eIn this mode, the BatteryProtect can be controlled by the VE.Bus BMS.\nNote: The BatteryProtect can also be used as a load isolator between a battery charger and a Li-ion battery. See the wiring diagram in the manual.\u003c\/p\u003e\n\u003cb\u003eExtremely low power consumption\u003c\/b\u003e\n\u003cp\u003eThis is important in the case of lithium-ion batteries, especially after switching off due to a low\nvoltage level.\nPlease also refer to our data sheet on lithium-ion batteries and the VE.Bus BMS manual for further\ninformation.\u003c\/p\u003e\n\u003cb\u003eOvervoltage protection\u003c\/b\u003e\n\u003cp\u003e\nTo prevent sensitive loads from being damaged by overvoltage, the load is always switched off\nwhen the DC voltage exceeds 16 V or 32 V.\u003c\/p\u003e\n\u003cb\u003eExplosion protection\u003c\/b\u003e\n\u003cp\u003e\nNo relays, but MOSFET switches, and therefore no sparking.\nDelayed alarm output\nThe alarm output is activated when the battery voltage falls below the preset value\nfor switching off for more than 12 seconds. Starting the engine therefore does not activate the alarm. The alarm output is a\nshort-circuit protected open collector output, which is connected to the negative (minus) rail. Max. current 50 mA.\nThe alarm output is normally used to activate an audible signal, an LED, or a relay.\u003c\/p\u003e\n\u003cb\u003eLoad disconnection and reconnection delay\u003c\/b\u003e\n\u003cp\u003e\nThe load is switched off 90 seconds after the alarm is activated. If the battery voltage rises\n(for example, after the engine has been started) back up to the connection threshold within this period, the load will not\nbe switched off.\nThe load is reconnected 30 seconds after the battery voltage has exceeded the specified voltage value for reconnection\nagain.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Incl. 19% VAT","offer_id":57255198130551,"sku":"300-3123","price":95.08,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12(3) of the German VAT Act.","offer_id":57255494517111,"sku":"300-3123","price":79.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/battery-protect-bp-220front-anglewebjpg-332384.jpg?v=1761420619"},{"product_id":"victron-batteryprotect-48v-100a","title":"Victron BatteryProtect 48V-100A","description":"\u003ch2\u003eBatteryProtect 48V 100A by Victron Battery Protection\u003c\/h2\u003e\n\u003cp\u003eThe BatteryProtect disconnects the battery from non-essential loads before it is fully discharged (which would damage it) or before it no longer has enough energy to start the engine.\u003cbr\u003eThe device is designed for 48 V batteries.\u003c\/p\u003e\u003cb\u003eEasy programming\u003c\/b\u003e\n\u003cp\u003eThe BatteryProtect can be set to switch on or off at several different voltages. The seven-segment display then indicates which setting has been selected.\u003c\/p\u003e\u003cb\u003eA special setting for lithium-ion batteries\u003c\/b\u003e\n\u003cp\u003eIn this mode, the BatteryProtect can be controlled by the VE.Bus BMS. Note: The BatteryProtect can also be used as a load break between a battery charger and a lithium-ion battery. See the wiring diagram in the manual.\u003c\/p\u003e\u003cb\u003eExtremely low power consumption\u003c\/b\u003e\n\u003cp\u003eThis is important in the case of lithium-ion batteries, especially after switching off due to a low voltage level. Please also refer to our data sheet on lithium-ion batteries and the VE.Bus BMS manual for further information.\u003c\/p\u003e\u003cb\u003eOvervoltage protection\u003c\/b\u003e\n\u003cp\u003eTo prevent sensitive loads from being damaged by overvoltage, the load is always switched off when the DC voltage exceeds 64 V.\u003c\/p\u003e\u003cb\u003eExplosion protection\u003c\/b\u003e\n\u003cp\u003eNo relays, but MOSFET switches, and therefore no sparking. Delayed alarm output The alarm output is activated when the battery voltage falls below the preset cut-off value for more than 12 seconds. Starting the engine therefore does not activate the alarm. The alarm output is a short-circuit protected open collector output, which is connected to the negative (minus) rail. Max. current 50 mA. The alarm output is normally used to activate an audible signal, an LED or a relay.\u003c\/p\u003e\u003cb\u003eLoad cut-off and reconnection delay\u003c\/b\u003e\n\u003cp\u003eThe load is switched off 90 seconds after the alarm is activated. If the battery voltage rises back to the reconnection threshold within this period (for example, after the engine has been started), the load will not be switched off. The load is reconnected 30 seconds after the battery voltage has exceeded the specified reconnection voltage value.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Incl. 19% VAT","offer_id":57255198196087,"sku":"300-3124","price":129.47,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12(3) of the German VAT Act.","offer_id":57255458996599,"sku":"300-3124","price":108.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/batteryprotect-48v-100a-front-anglepng-332385.png?v=1761420620"},{"product_id":"super-b-relais-tbs-rbs-12v500a","title":"Super B relay TBS RBS 12V500A","description":"\u003ch2\u003eSuper B Relay TBS RBS 12V500A\u003c\/h2\u003e\n\u003cp\u003eThe Super B Relay TBS RBS 12V500A is an intelligent magnetic high-current switch specifically designed for handling DC loads of up to 500 amperes. This powerful switch can be controlled via the Battery Communication Interface (BCI) and is perfectly suited for use with Nomada 12V105Ah batteries. Available in 12 VDC and 24 VDC versions, the TBS RBS offers a robust solution for high-current applications.\u003c\/p\u003e\n","brand":"Super B","offers":[{"title":"Incl. 19% VAT","offer_id":57251322462583,"sku":"502-1047","price":275.35,"currency_code":"EUR","in_stock":true},{"title":"Incl. 0% VAT pursuant to Section 12(3) of the German VAT Act.","offer_id":57255497105783,"sku":"502-1047","price":231.39,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/6770\/8791\/files\/502-1047superbtbsrbsjpg-334185.jpg?v=1761422623"}],"url":"https:\/\/solarkontor.de\/en\/collections\/relais.oembed?page=2","provider":"Solarkontor","version":"1.0","type":"link"}