Victron BatteryProtect 12/24V-220A

Victron BatteryProtect 12/24V 220A

The BatteryProtect function disconnects the battery from non-essential loads before it becomes fully discharged (which would damage it) or before it no longer has enough energy to start the engine.

  • Maximum uninterrupted load current: 220A
  • for 12V or 24V batteries
  • automatic voltage range detection
  • easy programming
  • extremely low power consumption
  • overvoltage protection
  • explosion protection

Sale price95,08 €

Tax included. Shipping calculated at checkout

SKU: 300-3123

In stock
Versandbereit in: 1 - 3 Werktagen

Product description

BatteryProtect 12/24V 220A by Victron Battery Protection

The BatteryProtect disconnects the battery from non-essential loads before it is fully discharged (which would damage it) or before it no longer has enough energy to start the engine.

12/24 V automatic voltage range detection

The BatteryProtect automatically detects the system voltage.

Easy programming

The BatteryProtect can be set to switch on or off at several different voltages. The seven-segment display then indicates which setting has been selected.

A special setting for lithium-ion batteries

In this mode, the BatteryProtect can be controlled by the VE.Bus BMS. Note: The BatteryProtect can also be used as a load isolator between a battery charger and a Li-ion battery. See the wiring diagram in the manual.

Extremely low power consumption

This is important in the case of lithium-ion batteries, especially after switching off due to a low voltage level. Please also refer to our data sheet on lithium-ion batteries and the VE.Bus BMS manual for further information.

Overvoltage protection

To prevent sensitive loads from being damaged by overvoltage, the load is always switched off when the DC voltage exceeds 16 V or 32 V.

Explosion protection

No relays, but MOSFET switches, and therefore no sparking. Delayed alarm output The alarm output is activated when the battery voltage falls below the preset value for switching off for more than 12 seconds. Starting the engine therefore does not activate the alarm. The alarm output is a short-circuit protected open collector output, which is connected to the negative (minus) rail. Max. current 50 mA. The alarm output is normally used to activate an audible signal, an LED, or a relay.

Load disconnection and reconnection delay

The load is switched off 90 seconds after the alarm is activated. If the battery voltage rises (for example, after the engine has been started) back up to the connection threshold within this period, the load will not be switched off. The load is reconnected 30 seconds after the battery voltage has exceeded the specified voltage value for reconnection again.