Victron Cyrix Li-charge 12/24V 230A battery coupler relay battery protection lithium

Intelligenter Batteriekoppler Cyrix Li-charge 12/24V 230A von Victron
  • Cyrix-Li-Charge: Überladungsschutz für Li-Ionen Batterien
  • für 12 und 24 V Systeme geeignet
  • zulässiger Dauerstrom: 230 A
  • extrem geringe Spannungsverluste
  • entwickelt für Li-Ionen Akkus

0% VAT according to §12 para. 3 UStG:

Further information on 0% VAT according to §12 para. 3 UStG

Sale price140,25 €

Tax excluded. Shipping calculated at checkout

SKU: 300-3197

In stock
Versandbereit in: 1 - 3 Werktagen

Product details

Victron Cyrix Li-charge 12/24V 230A battery coupler relay battery protection lithium

Intelligenter Batteriekoppler Cyrix Li-charge 12/24V 230A von Victron
  • Cyrix-Li-Charge: Überladungsschutz für Li-Ionen Batterien
  • für 12 und 24 V Systeme geeignet
  • zulässiger Dauerstrom: 230 A
  • extrem geringe Spannungsverluste
  • entwickelt für Li-Ionen Akkus

Product description

Cyrix battery coupler Li-ion series: Li-Charge

How the Cyrix-Li-Charge works

The Cyrix-Li-Charge connects a battery charger with a delay time of 3 seconds:

  • when the VE. Bus BMS "Charge Disconnect" output is high and
  • if it measures 13.7 V (or 27.4) or more at its battery charger terminal and
  • when it measures 2V or more at its battery terminal (the Cyrix remains open when not connected to the battery).

    The Cyrix-Li-Charge switches off immediately when its control input reaches the "free floating" state (open circuit), indicates a cell overvoltage or a cell overtemperature.
    Generally, a cell overvoltage alarm will reset shortly after charging is stopped. The Cyrix will then reconnect the charger after a 3-second delay. After two attempts to reconnect the device at 3-second intervals, this delay time is extended to 10 minutes.
    Whenever the battery voltage falls below 13.5V (or 27V or 54V), the Cyrix switches off with a delay of 1 hour.
    Note 1: If the discharge current is 0 or there is only a very low discharge current, the Cyrix will not switch off shortly after the charger is switched off and/or disconnected because the battery voltage remains above 13.5 V.
    Note 2: If the battery charger output immediately rises to 13.7V or more after the Cyrix has shut down, the Cyrix will restart with a delay of 3 seconds.

    Product features

    • Protects the battery from excessive discharge due to loads
    • Continuous current: 230 A
    • suitable for 12V and 24V systems, automatic detection
    • intelligent control by microprocessor 

DO YOU HAVE ANY FURTHER QUESTIONS?

Let our team advise you on your project. Non-binding and personalized.

GET ADVICE NOW