

Victron Cyrix Li-charge 12/24V 230A battery coupler relay battery protection lithium
Intelligenter Batteriekoppler Cyrix Li-charge 12/24V 230A von Victron
- Cyrix-Li-Charge: Überladungsschutz für Li-Ionen Batterien
- für 12 und 24 V Systeme geeignet
- zulässiger Dauerstrom: 230 A
- extrem geringe Spannungsverluste
- entwickelt für Li-Ionen Akkus
Tax included. Shipping calculated at checkout

Product details
Victron Cyrix Li-charge 12/24V 230A battery coupler relay battery protection lithium
Intelligenter Batteriekoppler Cyrix Li-charge 12/24V 230A von Victron
- Cyrix-Li-Charge: Überladungsschutz für Li-Ionen Batterien
- für 12 und 24 V Systeme geeignet
- zulässiger Dauerstrom: 230 A
- extrem geringe Spannungsverluste
- entwickelt für Li-Ionen Akkus
Manufacturer information and, if applicable, the responsible person:
Victron Energy
The Paal 35
1351 JG Almere
sales@victronenergy.com
https://www.victronenergy.com
Product description
Cyrix battery coupler Li-ion series: Li-Charge
How the Cyrix-Li-Charge works
The Cyrix-Li-Charge connects a battery charger with a delay time of 3 seconds:
- when the VE. Bus BMS "Charge Disconnect" output is high and
- if it measures 13.7 V (or 27.4) or more at its battery charger terminal and
- when it measures 2V or more at its battery terminal (the Cyrix remains open when not connected to the battery).
The Cyrix-Li-Charge switches off immediately when its control input reaches the "free floating" state (open circuit), indicates a cell overvoltage or a cell overtemperature.
Generally, a cell overvoltage alarm will reset shortly after charging is stopped. The Cyrix will then reconnect the charger after a 3-second delay. After two attempts to reconnect the device at 3-second intervals, this delay time is extended to 10 minutes.
Whenever the battery voltage falls below 13.5V (or 27V or 54V), the Cyrix switches off with a delay of 1 hour.
Note 1: If the discharge current is 0 or there is only a very low discharge current, the Cyrix will not switch off shortly after the charger is switched off and/or disconnected because the battery voltage remains above 13.5 V.
Note 2: If the battery charger output immediately rises to 13.7V or more after the Cyrix has shut down, the Cyrix will restart with a delay of 3 seconds.Product features
- Protects the battery from excessive discharge due to loads
- Continuous current: 230 A
- suitable for 12V and 24V systems, automatic detection
- intelligent control by microprocessor

DO YOU HAVE ANY FURTHER QUESTIONS?
Let our team advise you on your project. Non-binding and personalized.
GET ADVICE NOW



