Victron BatteryProtect 48V-100A

Victron Smart BatteryProtect 48V 100A

The smart BatteryProtect function protects the battery from deep discharge and can be used as a system on/off switch.

  • Maximum uninterrupted load current: 100 A
  • for 48V batteries
  • easy Bluetooth programming
  • extremely low power consumption
  • overvoltage protection
  • explosion protection

Sale price129,47 €

Tax included. Shipping calculated at checkout

SKU: 300-3124

In stock
Versandbereit in: 1 - 3 Werktagen

Product description

BatteryProtect 48V 100A by Victron Battery Protection

The BatteryProtect disconnects the battery from non-essential loads before it is fully discharged (which would damage it) or before it no longer has enough energy to start the engine.
The device is designed for 48 V batteries.

Easy programming

The BatteryProtect can be set to switch on or off at several different voltages. The seven-segment display then indicates which setting has been selected.

A special setting for lithium-ion batteries

In this mode, the BatteryProtect can be controlled by the VE.Bus BMS. Note: The BatteryProtect can also be used as a load break between a battery charger and a lithium-ion battery. See the wiring diagram in the manual.

Extremely low power consumption

This is important in the case of lithium-ion batteries, especially after switching off due to a low voltage level. Please also refer to our data sheet on lithium-ion batteries and the VE.Bus BMS manual for further information.

Overvoltage protection

To prevent sensitive loads from being damaged by overvoltage, the load is always switched off when the DC voltage exceeds 64 V.

Explosion protection

No relays, but MOSFET switches, and therefore no sparking. Delayed alarm output The alarm output is activated when the battery voltage falls below the preset cut-off value for more than 12 seconds. Starting the engine therefore does not activate the alarm. The alarm output is a short-circuit protected open collector output, which is connected to the negative (minus) rail. Max. current 50 mA. The alarm output is normally used to activate an audible signal, an LED or a relay.

Load cut-off and reconnection delay

The load is switched off 90 seconds after the alarm is activated. If the battery voltage rises back to the reconnection threshold within this period (for example, after the engine has been started), the load will not be switched off. The load is reconnected 30 seconds after the battery voltage has exceeded the specified reconnection voltage value.