Victron Centaur Charger 12/80 analogue battery charger 80A 12V
Centaur Charger 12/80 (3) 12 V from Victron
- Charging current: 80 A
- for 12 V batteries
- highest quality and robustness
- three powerful outputs
- usable worldwide (90V~ to 65V~ at 50/60 Hz)
Tax included. Shipping calculated at checkout
Your legal guarantee rights

Product description
Victron Centaur Charger for 12 V Batteries
The new Centaur battery charger range from Victron Energy has been developed for worldwide use.
Compliance with general requirements and input/output specifications are the main features of this new product range, which was designed by the renowned Dutch manufacturer. It was designed to meet both the requirements of the CE marking for Europe and the UL marking for the United States.
The Centaur range automatically accepts an input range from 90 to 265 VAC 50/60 Hz. This means the devices can be used anywhere in the world.
The Centaur model also operates at an input power of 90-400 VDC. This makes it a DC-DC charging converter that is perfectly suited for an electronic diesel system. Among other things, the model features a fully automatic three-stage charging curve, which ensures that the batteries are fully charged every time, as well as three separate charging outputs for equipment with multiple batteries, making it suitable for most typical installations.
Resilient device, quality without compromise
The aluminum enclosure with epoxy powder coating, drip protection against condensation and stainless steel mounting parts withstand the harshest conditions such as heat, moisture and saline atmospheres.
The circuit boards are securely protected against corrosion by an acrylic coating. Temperature sensors ensure that all power components operate within specified limits and, if necessary under extreme conditions, the output current is automatically reduced.
All models operate without special settings in a voltage range of 90 V to 265 V at both 50 Hz and 60 Hz. Thus, worldwide use is possible, regardless of the voltage and frequency range of the local grid.
Three outputs each with full output current
Three separate outputs for the simultaneous charging of three battery sets. Each output delivers the full current.
Three-stage charging curve with temperature compensation
Centaur initially charges with constant current (bulk) until the charging current has dropped to 70% of the rated value
Then follows a preset four-hour constant voltage phase, after which a maintenance charging phase follows. The charging voltage is regulated via the internal temperature sensor (-2mV/°C per cell).
With a DIP switch, the optimal charging voltage values can be set for the respective battery types (e.g. wet lead-acid battery, gel battery or AGM battery ).
Technical data
| Input voltage (V AC) | 90-265 |
| Power outputs | 3 |
| Charging current (A) | 80 |
| Recommended battery capacity (Ah) | 320-800 |
| Battery connections | M8 bolts |
| Weight | 12 kg |
| Dimensions mm (HxWxD) | 426x239x135 |
Product details & downloads
Manufacturer information and, if applicable, the responsible person:
Victron Energy
The Paal 35
1351 JG Almere
Email: sales@victronenergy.com
Website: https://www.victronenergy.com

Advice & Contact
Questions about the article?
If you have any further questions about the product or would like to contact us in general, please click the button and send us a message. We look forward to hearing from you!
GET ADVICE NOW