Victron Skylla-i 24/100 (3) 230V battery charger 100A 24V (3)
Victron Skylla-i 24/100 Battery Charger (3)
- three full-power charge current outputs
- for 24 V systems
- charges lead and lithium-ion batteries
- can also be used as a power supply
Tax included. Shipping calculated at checkout
Your legal guarantee rights

Product description
Victron Skylla-i Battery Charger for 24V Batteries
Skylla-i (3): three full power outputs for charging 3 battery banks.
The Skylla-i (3) features 3 separate outputs. All outputs can deliver the full rated output current.
The charging voltage can be precisely adjusted to any battery system. The charger input is 230 V at 50/60 Hz.
The charging voltage can be measured directly at the battery terminals to compensate for voltage drop due to cable resistance. An external sensor enables the measurement of the battery temperature and the corresponding compensation of the charging voltage.
Less maintenance and aging when the battery is idle: the storage mode
The storage mode is activated whenever no discharge has occurred within 24 hours. In storage mode, the float charging voltage is then reduced to 2.2 V/cell (26.4 V for a 24 V battery) to minimize gas generation and corrosion on the positive plates.
Once a week, the voltage is increased back to the constant voltage threshold to 'refresh' the battery. This achieves a kind of equalization charge that prevents electrolyte stratification and sulfation - the two main reasons for premature battery failure.
Robust
The epoxy powder-coated aluminum enclosure with drip protection and stainless steel brackets withstands even the harshest environmental conditions: heat, moisture, and salt-laden air. An acrylic coating protects the circuit boards as best as possible against corrosion.
Temperature sensors ensure that the power components are always operated within the specified limits. Under extreme environmental conditions, the output current is automatically reduced if necessary.
Prevention of damage due to excessive gas generation: battery protection mode
To shorten the charging time, the highest possible charging current in combination with a high constant voltage is aimed for. However, to avoid excessive gas generation towards the end of the constant current phase, the Skylla-i limits the rate of voltage increase after the gasing voltage has been reached.
Suitable for lithium-ion batteries (LiFePo4)
A simple on/off control can be installed by connecting a relay or an open-collector optocoupler output from a Li-Ion BMS to the remote control connection of the charger.
Alternatively, voltage and current can be fully controlled by establishing a connection to the galvanically isolated CAN-bus connection.
Battery voltage sensor
To compensate for voltage losses due to cable resistance, the Skylla-i has a voltage sensor in the charging circuit, so that the battery always receives the correct charging current.
Use as a power supply
Due to the perfectly stabilized output voltage, the Skylla-i can be used as a power supply when no batteries or large buffer capacitors are available.
Technical data
Product details & downloads
Manufacturer information and, if applicable, the responsible person:
Victron Energy
The Paal 35
1351 JG Almere
Email: sales@victronenergy.com
Website: https://www.victronenergy.com

Advice & Contact
Questions about the article?
If you have any further questions about the product or would like to contact us in general, please click the button and send us a message. We look forward to hearing from you!
GET ADVICE NOW