Victron Smart BatteryProtect 12/24V 65A deep discharge protection

Victron SmartBatteryProtect 12/24V 65A with integrated Bluetooth

The BatteryProtect function disconnects the battery from non-essential loads before it is fully discharged (which would damage it) or before it no longer has enough energy to start the engine.

  • Maximum uninterrupted load current: 65 A
  • for 12 or 24 V batteries
  • extremely low power consumption
  • overvoltage protection
  • programmable via Bluetooth

Sale price58,67 €

Tax included. Shipping calculated at checkout

SKU: 300-3121S

In stock
Versandbereit in: 1 - 3 Werktagen

Product description

SmartBatteryProtect 12/24V 65A by Victron Battery Protection with Bluetooth

The BatteryProtect disconnects the battery from non-essential loads before it is fully discharged (which would damage it) or before it no longer has enough energy to start the engine.

Bluetooth: Easy Programming
By using Bluetooth to program the Smart BatteryProtect, all required on/off thresholds can be set.
Alternatively, one of nine preset on/off thresholds can be set using the programming pin (see manual).
If necessary, the Bluetooth function can be disabled.

12/24 V automatic voltage range detection

The BatteryProtect automatically detects the system voltage.

Easy Programming

The BatteryProtect can be set to switch on or off at several different voltages. The seven-segment display then indicates which setting has been selected.

A special setting for lithium-ion batteries

In this mode, the BatteryProtect can be controlled by the VE.Bus BMS. Note: The BatteryProtect can also be used as a load breaker between a battery charger and a Li-ion battery. See the wiring diagram in the manual.

Extremely low power consumption

This is important in the case of lithium-ion batteries, especially after switching off due to a low voltage level. Please also refer to our data sheet on lithium-ion batteries and the VE.Bus BMS manual for further information.

Overvoltage protection

To prevent sensitive loads from being damaged by overvoltage, the load is always switched off when the DC voltage exceeds 16 V or 32 V.

Explosion protection

No relays, but MOSFET switches, and therefore no sparking. Delayed alarm output The alarm output is activated when the battery voltage falls below the preset cut-off value for more than 12 seconds. Therefore, starting the engine does not activate the alarm. The alarm output is a short-circuit protected open collector output connected to the negative (minus) rail. Max. current 50 mA. The alarm output is normally used to activate an audible signal, an LED, or a relay.

Load cut-off and reconnection delay

The load is switched off 90 seconds after the alarm is activated. If the battery voltage rises again to the reconnection threshold within this period (for example, after the engine has been started), the load will not be switched off. The load is reconnected 30 seconds after the battery voltage has exceeded the specified reconnection voltage value.